Horizontal Wall Junction

Horizontal Wall Junction

Wakaflex® should cover the tiles or slates by a minimum 150mm and turned up the wall for a minimum of 75mm.

Fold Wakaflex® according to the measurements above and remove one part of the backing film. Form this part to the tiles and ensure the edge with the butyl-strip is properly fixed to the tiles.

Then remove the rest of the backing film and form Wakaflex® to the wall. 

Any questions about applying our lead-free flashing or any other Haus Profi product? Just get in touch, we’re here to help.